MOLYTE C AUS TR ALI A, Un it 1, 9 Stee l St, Capa la ba, QLD A ustralia, 41 57 Material Safety Data Sheet ULTRALOC 3262 anaerobic Classified as hazardous according to criteria of NOHSC. Chemical Product / Company Identification ULTRALOC 3262 Thread Locker
10mL P/No. 326210, 50mL P/No. 326250, 250mL P/No 326225
Molytec Australia P/L 1/9 Steel St Capalaba QLD Australia 4157
Composition and Information on Harmful Ingredients Hazards Identification Relevant routes of exposure: Potential Health Effects Inhalation: Skin contact:
May cause allergic skin reaction. May cause skin irritation.
Eye contact:
Contact with eyes will cause irritation.
Ingestion:
Not expected to be harmful by ingestion.
HMIS: Health: FLAMMABILITY: 1 REACTIVITY: WARNING: CAUSES EYE IRRITATION. MAY CAUSE SKIN IRRITATION. MAY CAUSE ALLERGIC SKIN REACTION. MAY CAUSE RESPIRATORY TRACT IRRITATION. First Aid Measures Ingestion:
Do not induce vomiting. Keep individual calm. Obtain medical attention.
Inhalation:
Remove to fresh air. If symptoms develop and persists, get medical attention.
Skin contact:
Wash with soap and water. Remove contaminated clothing and shoes. Wash clothing before reuse. Get medical attention if symptoms occur.
Eye contact:
Flush with copious amounts of water, preferably lukewarm water, for at least 15 minutes, holding eyelids open all the time. Get medical attention.
Fire Fighting Measures Flash Point:
Greater than 93°C (200°F) Cleveland closed cup
Autoignition temperature: Flammable/Explosive limits –lower%: Flammable/Explosive limits –upper%: Extinguishing media: Special fire fighting procedures: Unusual fire or explosion hazards: Hazardous combustion products:
Oxides of carbon. Oxides of sulfur. Oxides of nitrogen. Irritating organic vapours.
Accidental Release Measures Environmental precautions:
Prevent product from entering drains or open waters.
Clean-up methods:
Soak up with inert absorbent. Store in partly filled, closed container until disposal.
Handling and Storage Handling:
Avoid contact with eyes, skin and clothing. Avoid breathing vapour and mist. Wash thoroughly after handling.
Storage:
For safe storage, store at or below 38°C (100°F). Keep in a cool, well ventilated area away from heat, sparks and open flame. Keep container tightly closed until ready for use.
Incompatible products: Exposure Control and Personal Protection (See Section 3 for exposure limits.) Engineering controls:
No specific ventilation requirements noted, but forced ventilation may still be required if concentrations exceed occupational exposure limits.
Respiratory protection: Use NIOSH approved respirator if there is potential to exceed exposure limit(s). Skin protection:
Use impermeable gloves and protective clothing as necessary to prevent skin contact. Neoprene gloves. Butyl rubber gloves. Natural rubber gloves.
Eye/face protection:
Safety goggles or safety glasses with side shields.
MOLYTE C AUS TR ALI A, Un it 1, 9 Stee l St, Capa la ba, QLD A ustralia, 41 57 Material Safety Data Sheet ULTRALOC 3262 anaerobic Physical and Chemical Properties Appearance & Odour: Vapour pressure: Boiling point/range: Melting point/range: Specific gravity: Vapor density: Evaporation rate: Solubility in water: VOC content: Stability and Reactivity Stability: Hazardous polymerisation: Hazardous decomposition products:
Oxides of carbon. Oxides of sulfur. Oxides of nitrogen. Irritating organic vapours.
Incompatibility:
Strong oxidizers. Free radical initiators. Strong reducing agents. Alkalis. Oxygen scavengers. Other polymerisation initiators. Copper. Iron. Zinc. Aluminium. Rust.
Conditions to avoid:
See “Handling and Storage” (Section 8) and “Incompatibility” (Section 11).
Toxicological Information
Toxicity data:Acute oral LD50 greater than 10,000 mg/kg (rat). Acute dermal LD50 greater than 5000 mg/kg (rabbit). Carcinogen Status Hazardous components NTP Carcinogen IARC Carcinogen OSHA Carcinogen
Sillica, amorphous, fumed, crystalline-free
Ecological Information Ecological Information: Not Available Disposal Considerations
Dispose of according to Federal, State and local government regulations.
Transport Information
Not classified as a Dangerous Good according to the Australian Code for the Transport of Dangerous Goods by Road and Rail.
Regulatory Information Other Information
Users should verify the currency of this data sheet if more than 5 years old. The information contained in this material safety data sheet is believed to be accurate on the date of issue and in accordance with the information available to us. Persons dealing with products referred to in this MSDS do so at their own risk. We accept no liability whatsoever for damage or injury however caused arising from use of this information or of suggestions contained herein.
POLICE AND FIRE BRIGADE:
For further safety information contact Denis Brown at MOLYTEC AUSTRALIA on: Tel: (07) 3245 2355 Fax: (07) 3245 2499 P.O. Box 5357, Alexandra Hills, QLD, Australia, 4161
Disclaimer The information contained within this MSDS applies only to the ULTRALOC product to which the sheet relates. The information provided is based on our best knowledge at the time of issue. The information contained within this MSDS is believed to be accurate and is given in good faith. However no warranty is made, either express or implied, regarding its accuracy or any liability arising out of the use of the information herein or the products supplied. When used in other preparations, formulations, or in mixtures, it is necessary to ascertain whether the classification of the hazards have changed. The attention of the user is drawn to the possibility of creating other hazards when the product is used for purposes other than that for which it was recommended. In such cases a reassessment may be necessary and should be made by the user. This safety data sheet should only be used and reproduced in order that the necessary measures are taken relating to the protection of health and safety at work. It is the responsibility of the handlers to pass on the totality of the information contained within this document to any subsequent person(s) who will come in to contact with, handle or use this product in any way. They should check the adequacy of the information provided within this MSDS before passing it on to their customers / staff. END OF DOCUMENT
To print: Select File and Then Print in your browser pul -down menus. Back to story Pain persists for Big Pharma in Q1 Analysts hoping for profit recovery in remainder of ’03 By Ted Griffith, CBS.MarketWatch.com Last Update: 4:24 AM ET April 12, 2003 NEW YORK (CBS.MW) -- It looks like the long-anticipated recovery in pharmaceutical profits will take a little longer. With
PURIFYING COMFORT MASQUE Keep skin cool, calm & hydrated For Red, Dehydrated, Uncomfortable Skin SKIN CONDITIONS DESCRIPTION Purify skin’s surface, dissolve dead cells, cool heat and redness and encourage skin to repair itself with this intensely hydrating, pore-purifying gelle masque. Ultra-soothing Lichochalcone from Chinese Licorice interrupts the biochemical cascade that